Automatic Tank Gauges

EVO™ 600 & EVO™ 6000

EVO 600 Hero.psd
EVO 600 Hero.psd EVO 600 Hero.psd
Automatic Tank Gauges

EVO™ 600 & EVO™ 6000

EVO™ 600 & EVO™ 6000 provide highly accurate inventory management and full-featured compliance monitoring for any size fuel system. Being module-based, the EVO™ Series is
highly configurable for site-specific probe and sensor requirements. Their simple setup and operation, remote connectivity, and advanced security features protect your fuel system while keeping you directly connected to vital site data whenever, and wherever. The highly-intuitive, full-color, icon-based touch screen provides user-friendly on-site access to inventory, alarm, and compliance data.

THE EVOLUTION CONTINUES

The new EVO 600 and EVO 6000 represent the next step in the evolution of Automatic Tank Gauges. Evolving with the changing needs of station owners and operators, the EVO™ 600 and EVO™ 6000 provide new capabilities to make fuel management even easier for every user.

EVO 600 All Apps Fade Launch Wide.psd
ALL NEW FEATURES

The EVO™ 6000 and EVO™ 6000 ATGs provide highly accurate inventory management and full-featured compliance monitoring for any size fuel system – plus advanced features like Corrosion Control™ System automation and monitoring, Electronic Line Leak Detection, and DEF/AdBlue® recirculation. Check out all of the new features available on the EVO™ 600 and EVO™ 6000.

TECHNICAL ADVANTAGES

EVO Corrision Control Illustration.png

NEW: Corrosion Control™ System

Proactively monitor for and remove corrosion-causing water from your fuel system with system automation and monitoring.

EVO600-Illustrations-multiplexer.psd

NEW: Multiplexing Sensor Hub

Add the Corrosion Control™ System or additional sensors to existing sites without having to break concrete to run new wires. 

EVO600-Illustrations-flowratemonitoring.psd

NEW: Flow Rate Monitoring

Detect and react to potential slow flow issues with automated daily reporting and alarms, helping to improve flow rates and dispenser throughput.

EVO600-Illustrations-security.psd

NEW: Security Features

Create unlimited user roles with customized access levels—all with individual user logins and tracking. The latest TLS/SSL protocols ensure data encryption between web browsers and the ATG.
EVO600-Illustrations-flowrate.psd

NEW: User Interfaces

Two additional One-Touch buttons, a shallower menu structure, and remote access via FFS PRO® Connect make navigation easy for every user-type.

EVO600-Illustrations-downtime.psd

NEW: Faster Processing

An all new faster processor enables the ATG to reboot in just seconds after firmware updates, keeping stations open and operational.

EVO-Highlights-Input-Capacity.png

Input Capacity

EVO™ 600 can support up to 36 sensors and 36 probes, while the EVO™ 6000 can support up to 72 sensors and 72 probes.

EVO-Highlights-Turbine-Pump-Interface.png

Turbine Pump Interface

Enhanced remote pump monitoring and control including pump-in-water automation, clogged intake escalation, tank leveling, and tank priority.

EVO-Highlights-Remote-Communication.png

Remote Communication

The FFS PRO® Connect web interface allows users to securely connect directly to an EVO™ Series ATG from any web enabled device.

EVO-Highlights-Inventory-Reconciliation.png

Inventory Reconciliation

Inventory Reconciliation is an automated leak detection function that analyzes tank volume, deliveries, and sales data to detect releases with a high level of accuracy.

EVO-Highlights-Tank-Autocalibration.png

Tank Autocalibration

Eliminate discrepancies in delivery reporting and daily reconciliations caused by inaccurate tank information programmed into the ATG with this function that automatically generates a highly accurate tank strapping chart.

EVO-Highlights-Electronic-Line-Leak-Detection.png

Electronic Line Leak Detection

Electronic line leak detection (ELLD) learns the characteristics of each line, eliminating possible configuration errors and ensures unparalleled leak detection accuracy.

EVO-Highlights-Def-Recirculation.png

DEF/AdBlue® Recirculation

Get automated control of your Diesel Exhaust Fluid (DEF) system while preventing frozen lines with energy and cost-saving recirculation functionality.

NEVER STOP EVOLVING

We are driven by our pursuit to innovate, simplify, secure, and connect every station owner to their fuel management system. EVO™ 600 and EVO™ 6000 ATGs feature simple setup and operation, remote connectivity, and advanced security features to protect your fuel system while keeping you directly connected to vital site data whenever, and wherever.

Highly Capable

EVO™ Series ATGs keep your site in compliance and protected from security threats with customizable user roles, user activity tracking, and up to 3-years of data back-up to protect against power outages or other system interruptions.

Simple Interface

A full-color 7” LCD touchscreen serves up one of the most intuitive user interfaces available with simplified user features you won’t find anywhere else.

Secure Data

EVO™ Series ATGs keep your site in compliance and protected from security threats with customizable user roles, user activity tracking, and up to 3-years of data back-up to protect against power outages or other system interruptions.

EVO 600 Series Group Wide.psd
SIMPLICITY & VISIBILITY

A full-color 7” LCD touchscreen serves up one of the most intuitive user interfaces available with simplified user features you won’t find anywhere else. You choose your home screen, you program your product colors, and you choose what shows up on your Favorites screen. Customize the interface to meet your business needs the way you operate. Check out the interactive demo below.

CLICK ON THE INTERACTIVE TOUCHSCREEN BELOW

EVO200 EVO400 Icon Based.psd

Icon-Based Design

Designed to be understood easily and operated intuitively. It’s simple to operate for new users and can reduce the amount of training required to operate.

EVO200 EVO400 One Touch.psd

One Touch Buttons

You can customize these home screen buttons to automate and carry out anything from complex, multi-function processes to simple daily delivery report generation - all with the touch of a single button.

EVO200 EVO400 Quick Jump.psd

Quick Jump Menu

Navigate quickly from application to application with ease. This time-saving menu makes the interface’s structure extremely shallow, simple to navigate, and reduces the amount of steps it takes to accomplish tasks.

EVO 600 Security Wide.psd
SYSTEM SECURITY

EVO™ Series ATGs help keep sites in compliance while providing marketers with the highest level protection from the security threats facing our industry.

Unlimited User Roles

Unlimited, customizable user roles and log-in security features protect against unwanted access while keeping track of user activity.

Data Protection

The latest in industry standard TLS/SSL protocols ensure data encryption between web browsers and the ATG.

Integrated Wifi

Optional integrated Wifi allows secure and protected onsite viewing of inventory levels for fuel delivery drivers.

EVO 600 TPI Wide.psd
TURBINE PUMP INTERFACE

Turbine Pump Interface is a powerful tool that creates a network between your Submersible Turbine Pump (STP) controllers and EVO™ Series ATGs. Through TPI, the tank gauge can be programmed to respond to faults in the submersible pumping system and react with intelligence that pump controllers alone cannot.

SEE TPI IN ACTION

Pump In Water Automation

When the water level in a tank approaches the pump intake, the tank gauge will enter alarm mode and automatically shut down the pump, protecting the system and consumers from water being pumped from that tank.

Leveling & Priority Modes

When managing two storage tanks of the same product ‘Leveling Mode’ can keep both tanks at the same percentage full without the use of a syphon bar between the two tanks.

Remote Pump Interaction

By networking the intelligent controllers to the fuel management system via TPI, a technician can remotely connect to the site to review the logged event history and view the status.

EVO 600 Advanced ELLD Wide.psd
ADVANCED FEATURES

EVO™ 600 and EVO™ 6000 ATGs offer additional advanced features and capabilites to manage your entire system as efficiently as possible.

WATCH THEM IN ACTION

AutoLearn™ Technology

Patented AutoLearn™ electronic line leak detection capability including Statistical Line Leak Detection for high throughput sites.

Corrosion Control™ System

Proactively monitor for and remove corrosion-causing water from your fuel system with system automation and monitoring powered by EVO™ 600 or EVO™ 6000 ATGs.

Streamlined Setup

Hardware auto-detection and wiring confirmation, multipoint tank charting, network printer auto-detection, and the ability to download and upload entire programming profiles from one ATG to another.

EVO 600 Flow Rate Wide.psd
FLOW RATE MONITORING

Improve dispenser throughput and maintain fast flow rates with the ability to detect and react to potential slow flow issues before they impact business with Flow Rate Monitoring. Available as a software option on new EVO™ Series ATGs or as a field upgrade option, Flow Rate Monitoring delivers ongoing flow rate performance data, flow rates for each fueling point, and provides a notification if transactions dip below a user-defined set point.

FLOW RATE MONITORING SELECTION GUIDE

Know Your Flow

Monitor for and ensure fast and consistent dispenser throughput with daily reports and alarm notifications regarding flow rate performance.

Performance Monitoring

Sales and dispensing duration data are automatically reconciled to help you better understand the flow performance of every fueling point.

Proactive Maintenance

Often, slow flow rates can indicate that a dispenser filter needs to be changed. Be proactive in calling for maintenance, getting dispensers back to peak performance sooner.

EVO 600 CCS Wide.psd
CORROSION CONTROL™ SYSTEM

The EVO™ 600 and EVO™ 6000 are compatible with the Corrosion Control™ Water Separator and Corrosion Detection Sensor, allowing owners to fully automate the removal of corrosion-causing water from tanks and monitor for corrosive environments.

VIEW THE CORROSION CONTROL™ SYSTEM
CCS - EVO GUI Hero.psd

Corrosion Control™ App

Get access to system data including Water Separator status, water levels, flow status, and more through the Corrosion Control™ Application, now standard on EVO™ 600 and EVO™ 6000 ATGs.

CCS - Corrosion Detection Sensor Hero.psd

Corrosion Detection Sensor

The Corrosion Control™ Corrosion Detection Sensor provides proactive automated detection and preventative notification of a corrosive environment in the tank ullage space.

EVO 600 Hero.psd

EVO™ Series Upgrade Kit

Get all the Corrosion Control System capabilities of the EVO 600 or EVO 6000 on an existing EVO 550 or EVO 5000 with the easy-to-install EVO Series Upgrade Kit.

EVO200 EVO400 Remote Wide.psd
REMOTE CONNECTIVITY

The FFS PRO® Connect web interface allows you to securely connect directly to your EVO™ Series ATG from any web enabled device. It automatically scales for tablets and smart phones, meaning no app to download.

INTERACTIVE DEMO
EVO Select Wide.psd
FIND THE RIGHT EVO™ SERIES ATG FOR YOUR SITE

The EVO™ Series family of ATGs offers four different options with right-sized features to meet the requirements of your specific application, size, and compliance needs. Which ATG is right for your application?

ATG SELECTION GUIDE

These module-based ATGs are highly configurable for site-specific probe and sensor requirements. Their simple setup and operation, remote connectivity, and advanced security features protect your fuel system while keeping you directly connected to vital site data whenever, and wherever. The highly-intuitive, full-color, icon-based touch screen provides user-friendly on-site access to inventory, alarm, and compliance data.

  • Allows you to make informed, data-driven inventory management decisions while keeping your site in compliance and protected from security threats.

  • Included Features: Inventory monitoring, Turbine Pump Interface (TPI) capability for enhanced and automated submersible turbine pump control, static tank testing, and containment compliance monitoring.

  • Optional Features: 24-hour Statistical Continuous Automatic Leak Detection (SCALD®), tank autocalibration, inventory reconciliation, and flow rate monitoring.

  • Patented AutoLearn™ electronic line leak detection capability including Statistical Line Leak Detection for high throughput sites.

 

  • Streamlined setup and programming includes hardware auto-detection and wiring confirmation, multipoint tank charting, network printer auto-detection, and the ability to download and upload entire programming profiles from one EVO™ to another.

  • Intuitive full-color 7" (17.78 cm) LCD touch screen interface provides simplified on-site access features including:
    • Up to Six (6) One Touch Buttons that are custom programmed to carry out common automated tasks with a single tap.
    • A Quick Jump Menu that allows you to quickly maneuver from application to application using a single button.
    • Programmable product colors for each tank.
  • FFS PRO® Connect allows you to remotely connect to your EVO™ from any web-enabled device.

  • Optional WiFi allows secure and protected on-site viewing of inventory levels for fuel delivery drivers.

  • Compatible with the Multiplexing Sensor Hub™ (FMP-MSH).

  • Compatible with Corrosion Control™ Water Separator.

  • Supports MQTT protocol, the standard for IoT messaging, for enhanced security of data transmission

Components

EVO600 Dims Comps 2023.psd
  • There can only be three types of one module, except for the UDP Module, which allows for up to six in an EVO™ or Expansion Console.
  • If you require more than three types of one module (other than the UDP Module) in an EVO™ or Expansion Console, please contact your FFS sales representative to review your needs.
  • The intrinsically safe barrier must be installed in the third slot or greater. (The third slot after the power supply module.)

1.   Cover

2.   LCD Touch Screen

3.   LED Indicators

4.   Printer

5.   Mounting Tabs

6.   Cooling Vents

7.   Module Slots

8.   Communication Ports

9.   Annunciator (audible alarm)

10. Ethernet Port 1

11. Ethernet Port 2

12. USB Port (Type-A)

13. USB Port (Mini-B)

14. RS-232 Comm Port 1

15. WiFi

16. Bus Extension

17. RS-232 Comm Port 2

18. RS-485 / TPI

19. Controller Module

20. Power Supply Module

21. AC Input Module (TS-ACI)

22. 10 Amp Relay Module (TS-10ARLY)

23. I/O Module (TS-IO)

24. 4-20mA Module EXP (TS-420EXP)

25. Relay Module (TS-RLY)

26.Blank

27.Intrinsically Safe Barrier

28.Probe Module (TS-PRB)

29.4-20mA Module (TS-420IB)

30.2-Wire Sensor Module (TS-2WSNS)

31.3-Wire Sensor Module (TS-3WSNS)

32.RS-485 Module (FMP-485IS)

33.UDP Module (FMP-UDP9)

Specifications

Maximum tanks monitored (stand-alone)    48 (EVO™ 600) / 72 (EVO™ 6000)
Maximum tanks monitored, with accessories    132* (EVO™ 600) / 168* (EVO™ 6000)
Maximum sensor input capacity (stand-alone)    48 (EVO™ 600) / 108 (EVO™ 6000)
Maximum sensor input capacity, with accessories   
180* (EVO™ 600) / 244* (EVO™ 6000)
Maximum total inputs (stand-alone)    72 (EVO™ 600) / 132 (EVO™ 6000)

Maximum total inputs, with accessories   

276* (EVO™ 600) / 336* (EVO™ 6000)

Maximum AC input channels (stand-alone)   
36 (EVO™ 600) / 36 (EVO™ 6000)
Maximum AC input channels, with accessories    72* (EVO™ 600) / 72* (EVO™ 6000)
Maximum relay output channels (stand-alone)    26 (EVO™ 600) / 26 (EVO™ 6000)
Maximum relay output channels, with accessories    50* (EVO™ 600) / 50* (EVO™ 6000)
Dry contact input channels    2
Connectivity    Ethernet (qty 2). RS-232, RS-485, standard USB, Mini-B USB
Display type    7" (17.78 cm) color LCD touch screen
Printer type    Thermal (also network or USB)
Alarm    Internal audible alarm
LEDs    Alarm, warning, and power
Applicable liquids    Petroleum, chemicals, and waste
Level units    Inches, centimeters, and millimeters
Volume units    Gallons or liters (mass with density option)
Power requirements    110 to 240 VAC, 50/60 Hz, 1.5 Amps
Operating temperature    32° to 104° F (0° to 40° C)
Humidity    0-90% non-condensing
EVO™ 600    H: 11.75"(300 mm), W: 10¼"(260 mm), D: 9"(229 mm)
EVO™ 6000    H: 11.75"(300 mm), W: 16½"(419 mm), D: 9"(229 mm)
Alarm set points    High/low product, water, and temperature
Technical Advantages   Inventory reconciliation/tank autocalibration/flow rate monitoring
Measurements    Density, mass, and phase separation measurement
Notifications    Email and SMS
Programming    Back-up generator monitoring/conditions
Advanced Logic Control    DEF/AdBlue® recirculation system
Support    MODBUS™
Approvals    UL, cUL, ATEX, IECEx, GSA IT Security
Certifications   
  • Third party certification of leak detection capabilities
  • Third party verified “MATURE” security posture level

*Requires use of FMP-EXPC Expansion Modules and/or FMP-MSH Multiplexing Sensor Hubs.

Ordering Guide

EVO™ model, software and hardware options can be listed separately or combined when ordering. Systems shipped from the factory will list the combined part number. Complete part numbers have a specific order and are created using the following guidelines:

EVOX DPWIE / TRFLGC

  • EVOX = Base Model Options
    • EVO600 = EVO™ 600 base ATG
    • EVO6000 = EVO™ 6000 base ATG
  • DPWIE = Hardware Options (choose all that apply)*
    • D = Display
    • P = Printer
    • W = Wifi
    • I = Dispenser interface module
  • TRFLGSC = Software Options (choose all that apply)
    • T = SCALD 24-hour tank testing
    • R or F
      • R = Reconciliation/Autocalibration
      • F = Reconciliation/Autocalibration with Flow Rate Monitoring
    • L or G
      • L = Line leak detection
      • G = Generator Line Leak Detection
    • S = Secondary Containment Monitoring
    • C = DEF/AdBlue® recirculation, enhanced logic conditions including value, counter, value compare, and latch

Example: EVO600DPWI/TRL = EVO™ 600 base model with display, printer, WiFi, Dispenser Interface Module, SCALD®, Reconciliation/Autocalibration, and line leak detection.

Module Selection Guide

Download the guide now.

EVO™ Module Selection Guide

EVO™ 600 and EVO™ 6000 Interface Modules

The EVO™ 600 and EVO™ 6000 come standard with a power supply module and a controller module. Additional interface modules can be installed. Interface modules ordered with an EVO™ will be installed at the factory. If you would like them to not be installed, please order the spare/replacement version of the module. The following guidelines must be followed:

  • EVO™ 600: Six total modules can be installed with a maximum of four intrinsically safe modules and a maximum of three of any one kind of module, except for the UDP Module, which allows for a maximum of four modules.
  • EVO™ 6000: Eleven total modules can be installed with a maximum of nine intrinsically safe modules and a maximum of three of any one kind of module, except for the UDP Module, which allows for a maximum of six modules.

Note: Do not include the Power Supply and Controller Modules when calculating total modules allowed.

Maximum UDP Modules Allowed to Run Concurrently with Probe Modules in a Single EVO™ Console or Expansion Console

The UDP Module is intended to replace the Probe Module for all new system orders. If you are planning to add UDP Modules to an existing EVO™ 600/6000 with Probe Modules, please adhere to the following table:

Existing Probe Modules Allowable UDP Modules
0 6
1 4
2 2
3 0

Intrinsically Safe Modules

Model Number Description
FMP-485IS Pre-installed RS-485 Module | 4 MSH inputs (allows for 24 total inputs) | Compatible with FMP-MSH multiplexing sensor hubs (EVO™ 600/6000 only)
FMP-UDP9 Pre-Installed UDP Module | 12 inputs | Compatible with FMP-LL3-XXX and FMP-LL3-XXX-I probes, FMP-UHS and FMP-ULS sensors, and FMP-XXX-U sensors (EVO™ 600/6000 only)
TS-2WSNS Pre-Installed 2-Wire Sensor Module | 12 inputs | Compatible with FMP-HFS2, FMP-UHS, FMP-ULS, TSP-HLS-XX, and TSP-HLS-XX/SS sensors
TS-3WSNS Pre-Installed 3-Wire Sensor Module | 8 inputs | Compatible with FMP-DDS*, FMP-DIS*, FMP-DTS*, FMP-EIS*, FMP-HIS*, FMP-HIS-XL*, FMP-UHS*, FMP-ULS*, TSP-DVS, TSP-HLS-XX, and TSP-HLS-XX/SS sensors
TS-PRB Pre-Installed Probe Module | 12 inputs | Compatible with TSP-LL2-XXX, TSP-LL2-XXX-I, FMP-LL3-XXX, and FMP-LL3-XXX-I probes; TSP-DMS-XX and FMP-XXX-U sensors; and VFM vapor flow meters
TS-420IB Pre-Installed 4-20 mA Module | 8 inputs | Intrinsically Safe | Compatible with TS-LSU500/X transducers and FMP-TEM, TS-VPS, and TS-SCCM sensors
  • -U sensors are not supported on the 2-wire or 3-wire sensor module.

Non-Intrinsically Safe Modules

Model Number Description
TS-10ARLY Pre-Installed 10 Amp Relay Module | 6 outputs | 10 Amp | Compatible with high power dispenser shutdown control functions
TS-420EXP Pre-Installed 4-20 mA Module | 8 inputs | Explosion-Proof | Compatible with TS-LSU500/X transducers and FMP-TEM, TS-VPS, and TS-SCCM sensors
TS-ACI Pre-Installed AC Input Module | 12 inputs | Compatible with dispenser hook signal monitoring functions
TS-IO Pre-Installed Input Output Module | 4 4-20 mA outputs | 8 3-240 VAC/DC inputs | Compatible with remote monitoring control and building monitoring system interfacing functions
TS-RLY Pre-Installed Relay Module | 8 outputs | 2 Amp | Compatible with TS-LSU500/X transducers, TPI, and TS-SCCM control functions
  • TS-RLY Module is not required for STP control when utilizing turbine pump interface (TPI) communications. The TS-420EXP module requires Controller Module software version 9.5 or greater Do not include Power Supply and Controller Module when calculating total modules allowed.

Expansion Consoles

The EVO-EXPC2 must follow the same guidelines as the EVO™ 600, and the EVO-EXPC must follow the same guidelines as the EVO™ 6000.

Model Number Description
EVO-EXPC Secondary console to add eleven additional plug-in modules to the primary TS-550, TS-5000, EVO™ 550, EVO™ 5000, EVO™ 600, EVO™ 6000 ATG, comes without a display or printer
EVO-EXPC2 Secondary console to add six additional plug-in modules to the primary TS-550, TS-5000, EVO™ 550, EVO™ 5000, EVO™ 600, EVO™ 6000, comes without a display or printer

EVO™ 600 & EVO™ 6000 Hardware & Software Field Upgrades

The following software and hardware options can be added to customize your EVO™ once it's been installed in the field.

Hardware Field Upgrades

Model Number Description
EVO-DISPREP Display upgrade for an EVO™ 600/6000, EVO™ 550/5000 with existing Interface Board REV 4 or lower
EVO-TMPTR Thermal internal printer assembly upgrade for an existing EVO™ 600/6000, EVO™ 550/5000, comes with one roll of printer paper
FMP-WIFI WiFi upgrade for an existing EVO™ 200/400, EVO™ 600/6000, includes 4.5" antenna
EVO-DIMIB Internal Dispenser Interface Module upgrade for an existing EVO™ 600/ 6000, dispenser interface cable must be ordered separately

Dispenser Interface Module Cables

Model Number Description
TSP-BDCBL Bennett® 515 only cable
TSP-GDCBL Gilbarco™ cable
TSP-GSDCBL Gilbarco™ G-Site™ cable
TSP-WDCBL Wayne™ cable

Internal Software Field Upgrades

Model Number Description
TS-TT Statistical Continuous Automatic Leak Detection (SCALD®) 24-hour tank testing
TS-TRAC Tank inventory reconciliation and autocalibration
TS-TRAC-F Reconciliation/autocalibration and flow rate monitoring
TS-FLOW Flow rate monitoring
TS-ELLD Electronic line leak detection
TS-ELLD-G Electronic line leak detection for generator applications
TS-SCM Secondary containment monitoring
TS-CON Enhanced logic conditions including value, counter, value compare, latch, and DEF/AdBlue® recirculation
  • Customers interested in SCM should see our EVO 550/5000 gauges.
  • TS-CON also appropriate for DEF/AdBlue® recirculation.

EVO™ Series Upgrade Kit

Get all the Corrosion Control System capabilities of the EVO600 or EVO™ 6000 on an existing EVO550 or EVO5000 with the easy-to-install EVOSeries Upgrade Kit.

Model Number Description
EVO-600UPG Upgrade kit for EVO™ 550 to EVO™ 600, includes control module, comm port cover, and EVO 600™ jewel
EVO-6000UPG Upgrade kit for EVO™ 5000 to EVO™ 6000, includes control module, comm port cover, and EVO 6000™ jewel
EVO-600UPG-W Upgrade kit for EVO™ 550 to EVO™ 600 with Wifi, includes control module, comm port cover, Wifi hardware, and EVO 600™ jewel
EVO-6000UPG-W Upgrade kit for EVO™ 5000 to EVO™ 6000 with Wifi, includes control module, comm port cover, Wifi hardware, and EVO 6000™ jewel
  • Note: The serial number of the existing EVO™ must be provided when ordering an EVO™ Series Upgrade Kit.

EVO™ 600 and EVO™ 6000 Replacement Parts

Model Number Description
FMSP-485IS Spare/Replacement RS-485 Module
FMSP-UDP9 Spare/Replacement UDP Module
TSSP-2WSNS Spare/Replacement 2-Wire Sensor Module.
TSSP-3WSNS Spare/Replacement 3-Wire Sensor Module.
TSSP-420IB Spare/Replacement 4-20mA Module, Intrinsically Safe
TSSP-10ARLY Spare/Replacement 10 Amp Relay Module
TSSP-420EXP Spare/Replacement 4-20mA Module, Explosion-Proof
TSSP-ACI Spare/Replacement AC Input Module
TSSP-IO Spare/Replacement Input/Output Module
TSSP-RLY Spare/Replacement Relay Module
EVO-6CM Spare EVO 600/600 controller module, standard features only, no software options
EVO-6CM/R Replacement EVO 600/6000 controller module, factory programmed with required options
EVO-6CM-W/R Replacement EVO 600/6000 controller module w/ Wifi, factory programmed with required options
TSSP-EXPPS Expansion console power supply
TSSP-PS Power supply module
EVO-DISPREP Display upgrade for an EVO™ 600/6000, EVO™ 550/5000 with existing Interface Board REV 4 or lower
EVO-TMPTR Thermal internal printer assembly upgrade for an existing EVO™ 600/6000, EVO™ 550/5000, comes with one roll of printer paper
TS-DIMIB (I) Internal dispenser interface module, dispenser interface cable must be ordered separately
TSSP-TRMBLK Package of 10 assorted terminal blocks
TSSP-PRB Spare/Replacement Probe Module
EVO-EXPC Secondary console to add eleven additional plug-in modules to the primary TS-550, TS-5000, EVO™ 550, EVO™ 5000, EVO™ 600, EVO™ 6000 ATG, comes without a display or printer
EVO-EXPC2 Secondary console to add six additional plug-in modules to the primary TS-550, TS-5000, EVO™ 550, EVO™ 5000, EVO™ 600, EVO™ 6000, comes without a display or printer
TS-LON (E) EcheLON™ communication module, IFSF protocol capability
TS-MDMIB (M) Internal modem, includes fax and data software capability
  • The serial number of the old CM must be provided when ordering the EVO-6CM/R or the EVO-6CM-W/R.
  • Only one TS-DIM or TS-LON module can be installed per ATG.

Manuals

Title Type Size
TB0721-02 Upgrading EVO2004006006000 Firmware.pdf PDF 0.59 MB
TB0123-02 Upgrading EVO 200_400_600_6000 Software Registration.pdf PDF 0.85 MB
TB0323-02 Connect External Printer to EVO Series Console.pdf PDF 0.24 MB
10000004821 EVO 600_6000 Upgrade Quick Reference.pdf PDF 1.56 MB
10000002562 EVO 6006000 Automatic Tank Gauges Operation Guide.pdf PDF 4.11 MB
10000007311 EVO 600_6000 Controller Module Replacement Guide.pdf PDF 1.35 MB
228180033 EVO 6006000 ATG Installation Guide.pdf PDF 2.58 MB
228180061 EVO 600-6000 Programming Guide.pdf PDF 3.23 MB
10000007526 EVO Postive Shutdown Reference Guide.pdf PDF 2.55 MB
000-0327 Multiplexing Sensor Hub Installation Guide.pdf PDF 3.24 MB
000-9308 r3 FMP-CDS Corrosion Detection Sensor Installation Guide.pdf PDF 8.12 MB
10000010405 EVO Series LCD & Display-Interface Board Installation Guide.pdf PDF 7.25 MB
TB1122-01 EVO™ 600 or EVO™ 6000 to Gilbarco Passport System Connection Instructions.pdf PDF 0.26 MB
10000005013 EVO 600_6000 Read This First.pdf PDF 0.07 MB
AG-021 TS-CON Control Conditions Software Application Guide.pdf PDF 2.5 MB
10000011156 MODBUS Interface Programming Guide.pdf PDF 0.62 MB
10000017488 EVO Series LCD Install Guide.pdf PDF 4.63 MB
10000014113 EVO Series Console Install Checklist PDF 0.09 MB
TB0124-01 EVO 2_4_6 Autocalibration.pdf PDF 0.65 MB

Drawings

Title Type Size
CD_FMS_TS-EXPC_001.pdf PDF 0.09 MB
CD_FMS_TS-EXPC_001.dwg DWG 0.48 MB
CD_FMS_EVO600_001.pdf PDF 0.1 MB
CD_FMS_EVO600_001.dwg DWG 0.38 MB

Assets