Recirculation System

EVO 600 DEF App Hero.psd

Recirculation System

Because DEF will freeze at around 12° F (-11° C), no DEF system is complete without a means to prevent it from freezing in the lines. When temperatures drop, EVO™ recirculates the fluid – preventing it from freezing in the lines.

EVO 600 DEF App Wide.psd
DEF RECIRCULATION MONITORING

The DEF Recirculation application, available on EVO™ 600 and EVO™ 6000, allows users to automate the recirculation of DEF as a means to prevent freezing while also providing DEF inventory management and line monitoring capabilities.

Temperature Thresholds

Select user-defined temperatures at which recirculation is both triggered and shutoff, allowing EVO™ to automate operation and navigate fluctuating environmental temperatures in an energy efficient manner.

System Status

Get a quick snapshot of key system performance indicators, line temperatures, recirculation status, and inventory levels.

Automated Alerts

Should EVO™ detect a drop in inventory levels during a recirculation period without dispenses, the app can issue an alarm, ensuring timely detection of potential product leaks. 

DEF STP - Performance.psd
MAXIMUM ENERGY EFFICIENCY

Instead of turning on a heated-pipework system at the beginning of winter and constantly running it, the temperature sensors in the DEF recirculation system will trigger the system to only run when it’s absolutely needed.

Efficient Operation

With no need to constantly heat the entire system, the DEF recirculation system only consumes energy as needed.

Energy Savings

Avoid high energy bills during the colder winter months that can result from heated pipe systems.

System Automation

Even with fluctuating temperatures of spring and fall, the system will know when it’s time to run.

EVO™ Series DEF Recirculation System

The DEF recirculation system is available as software option on EVO™ Series ATGs that includes recirculation, scheduling, and timer conditions.

  • For new ATGs, include internal software option "C".
  • For existing ATGs, order TS-CON.
  • A 6" temperature sensors with ½" NPT compression fitting installation hardware (FMP-TEM) is also required. 
  • An 8 input 4-20 mA module (TS-420IB) for the sensor (FMP-TEM), is also required.

 

DEF Recirculation System Sump Kits

Model Number Description
407513941 In-line dispenser DEF recirculation system kit for Gilbarco® Encore®DEF dispensers (includes LMM-3617-DEF and all components)
407513942 Tee dispenser DEF recirculation system kit for Gilbarco® Encore®DEF dispensers (includes LMM-3617-DEF and all components)
407513943 In-line dispenser DEF recirculation system kit for Wayne® Vista™DEF dispensers (includes LMM-2916-DEF and all components)
407513944 Tee dispenser DEF recirculation system kit for Wayne® Vista™DEF dispensers (includes LMM-2916-DEF and all components)