Remote Control Solution
Remote Control Solution
The Power Integrity™ Remote Control Solution (RCS) combines the required fueling control panel including dispenser/pump disconnects, dispenser hook isolation, low voltage dispenser data disconnects, and E-stops into a single panel while also providing advanced device power status monitoring, remote E-Stop engagement, and remote power resetting capabilities for fuel system and C-Store critical assets.
With OVERSITE™ remote monitoring and power cycling capabilities, C-Store operators can remotely reset fuel dispensers, site controllers, submersible pumps, and more, significantly reducing the need for costly on-site maintenance trips and helping to eliminate the expenses associated with extended downtime.
Increased Uptime
With early notification of device outages and E-Stop engagements, the RCS allows operators to reset equipment quickly and mitigate the impacts to business.
Cost Avoidance
The RCS can help decrease overall maintenance spending and operational costs by minimizing truck rolls and reducing asset downtime.
Workload Efficiency
C-store operators can leverage the RCS to improve downed asset troubleshooting, minimize on-site personnel involvement, and reduce service team deployment.
OVERSITE™ is an advanced device networking technology which enables remote monitoring and control of critical assets. This innovative technology offers a solution for overseeing site devices, streamlining operations, and enabling timely responses to potential issues and outages.
Traditional Systems
Traditionally, fuel system and C-store critical assets have been directly wired to circuit breakers with in-line E-Stops. Interactions with E-Stops and power cycling had to happen physically at the site, requiring a service call.
OVERSITE™ Systems
With OVERSITE™, the RCS serves as a central hub that controls and monitors essential site asset power connections and interfaces them with the EVO™ Series console, enabling remote monitoring, and control.
Through the FFS PRO® Connect Web Interface, operators can access the tools to monitor and control their critical assets remotely. All of these features are included with purchase with no recurring subscription fees:
E-Stop initiation and monitoring
Asset power cycling and power cycling sequencing
Power status monitoring
User-defined email and SMS event notifications
Event/outage tracking and custom report generation
Automated event response triggers
Sequencing is often required to complete a proper communication handshake between systems like dispensers, distribution boxes, and price signs which require the careful communication between several individual site devices.
What Is Sequencing
Sequencing involves applying power to individual system components in a specific cadence to ensure proper functionality.
Manual Sequencing
Traditionally, bringing downed systems back online through sequencing had to happen physically at the site level, requiring a service call.
Remote Sequencing
The RCS pre-programmed remote sequencing capability automates the sequencing process and can be executed remotely, eliminating a service call.
INTEGRATED PROTECTION
The RCS combines NEC® required site and personnel protection devices into a single, integrated panel. Integrated protection functionalities include:
- Emergency disconnects controlled by E-Stop system
- Dispenser hook isolation
- E-Stop push button and reset button
- Low voltage dispenser disconnects:
- Dispenser data
- Intercom data
- Media/Network data
- Dispenser data
OVERSITE™ Critical Asset Network
With OVERSITE™, the RCS serves as a central hub that controls and monitors essential site asset power connections and interfaces them with the EVO™ Series console, enabling remote notifications, monitoring, and control functionalities.
1. EVO™ Series Console
2. Remote Control Solution
3. Circuit Breakers
4. Fueling Controller
5. Pump Controllers
6. E-Stops
7. Dispensers
8. Price Sign
Environmental
Operating Temperature | -40° C to 45° C (-40° F to 113° F) |
Storage Temperature | -40° C to 85° C (-40° F to 185° F) |
Operating Humidity | 0 to 90% relative humidity |
Dimensions - Enclosed RCS | 60" H x 30" W x 7" D |
Weight - Enclosed RCS | 200 lbs (90.7 kg) or less |
Line Voltage | 110-120 V |
Line Frequency | 50-60 Hz |
Location | Install the unit indoors, in a non-hazardous environment |
Circuit Breaker | 20A dedicated circuit breaker required |
Approvals/Certifications | UL 508A |
1-Ph Modules
Input Terminals | 1 (Line and Neutral) |
Output Terminals | 1 (Line and Neutral) |
Operating Voltage | 100-240 VAC |
Operating Current | 15A AC |
Operating Frequency | 50/60Hz |
Pump Modules
Input Terminals | 3 |
Output Terminals | 3 |
Operating Voltage | 100-240 VAC |
Operating Current | 35A Resistive, 250 VAC 5HP |
Operating Frequency | 50/60Hz |
ACIO Module
Input Terminals | 4 (Line and Neutral) |
Output Terminals | 2 (Supply and Output) |
Operating Voltage | 100-240 VAC |
Operating Input Current | 35 mA |
Operating Output Current | 0.3 A |
Operating Frequency | 50/60Hz |
NEC® Compliance
Emergency Disconnects Controlled by E-Stop |
NEC® 514.11 & NFPA® 30A |
Dispenser Hook Isolation | NEC® 514.13 |
Low Voltage Dispenser Data Disconnects | NEC® 514.13 |
System Components
1. Pump Power Module(s) (E-Stop controlled)
2. Dispenser Power Module(s) (E-Stop controlled)
3. Auxiliary Single Phase Power Module(s) (Separate from E-Stop)
4. AC Isolation Modules:
- Dispenser Hook Isolation Modules
- E-Stop Push Button Identification Module
5. Low Voltage Dispenser Disconnect
6. Health Monitoring Controller (HMC)
7. Fuse Holder for Control Circuit
8. Fuse Holder for E-Stop Circuit
9. E-Stop Push Button
10. E-Stop Reset Push Button
Remote Web Interface
Through the FFS PRO® Connect Web Interface, operators can access the tools to monitor and control their critical assets remotely.
- Remotely power cycle assets
- Program and initiate power cycling sequences
- Generate user-defined email and SMS notifications
- Track outage events
- Create custom reports
Ordering Guide
Complete part numbers have a specific order and are created using the following guidelines. Replace any bold character with the chosen option(s).
RCS - XDN YPNN - NDGT NCB NEQR - FZANT NKL
RCS = Remote Control Solution
XDN = # of Dispensers
- 04 = 4 Dispensers
- 08 = 8 Dispensers
- 12 = 12 Dispensers
- 16 = 16 Dispensers
YPNN = # of Pumps
- 2 = 2 Pumps
- 3 = 3 Pumps
- 4 = 4 Pumps
- 5 = 5 Pumps
- 6 = 6 Pumps
- 7 = 7 Pumps
- 8 = 8 Pumps
NDGT NCB NEQR = Low Voltage Disconnect Options
N or D or G or T = Dispenser Data (Choose One)
- N = No Dispenser Data Disconnect
- D = Twisted Pair (No data surge protection)
- G = Twisted Pair with data surge protection for current loop
- T = Ethernet
N or C or B = Intercom Data (Choose One)
- N = No Dispenser Intercom Disconnect
- C = 4 conductors per dispenser
- B = 8 conductors per dispenser
N or E or Q or R = Media/Network Data (Choose One)
- N = No Dispenser Media Disconnect
- E = Ethernet
- Q = 4 conductors per dispenser
- R = 8 conductors per dispenser
F = Full Enclosure
ZANT = # of Extra 120V, 15A, 1-Phase Modules (Control 4 Devices Each)
- N = No extra 120V 1-Phase Modules
- 1 = 1, 120V 1-Phase Modules (4 devices total)
- 2 = 2, 120V 1-Phase Modules (8 devices total)
- 3 = 3, 120V 1-Phase Modules (12 devices total)
- 4 = 4, 120V 1-Phase Modules (16 devices total)
N or K or L = Extra Isolation Modules (Choose One)
- N = No Extra Isolation Modules
- K = 2 Extra Isolation Modules (4 inputs, 2 outputs each)
- L = 4 Extra Isolation Modules (4 inputs, 2 outputs each)
Example: RCS-04DN3PNN-TBE-F2ANTK = 4 dispensers, 3 pumps, Ethernet dispenser data disconnect, 8 conductors per dispenser intercom data disconnect, Ethernet media/network data disconnect, (2) 120V 1-phase modules, 2 extra isolation modules.
Featured
Brochures
Title | Type | Size | |
---|---|---|---|
FFS-0961 Remote Control Solution Brochure.pdf | 3.83 MB | ||
FFS-0962 Remote Control Solution Datasheet.pdf | 2.11 MB | ||
FFS-0971 Configured Controls Selection Guide.pdf | 4.1 MB | ||
FFS-0972 Remote Control Solution Cost Avoidance - ROI Brochure.pdf | 2.63 MB |
Catalogs
Title | Type | Size | |
---|---|---|---|
FFS-0834 Power Integrity Integrated Electrical Controls Catalog.pdf | 47.96 MB |
Manuals
Title | Type | Size | |
---|---|---|---|
TB0324-02 RCS Wiring Map.pdf | 0.12 MB | ||
10000016078 RCS Install Guide.pdf | 6.14 MB | ||
10000016079 RCS Programming Guide.pdf | 3.2 MB | ||
10000017424 RCS Operation Guide.pdf | 3.2 MB |