Primary Disconnects

Ethernet Disconnects

Ethernet Primary Disconnects.psd
Primary Disconnects

Ethernet Disconnects

By connecting to the site’s emergency stop system, Ethernet Primary Dispenser Disconnects provide low voltage disconnection for dispensers that use Ethernet network cabling for primary dispenser communication. Models are available that will disconnect 1 or 2 Ethernet cables for 8 dispensers or disconnect one Ethernet cable for 16 dispensers.

Ethernet Primary Disconnects - Rack Mounted - Open - Hero.psd

PRIMARY DISCONNECTS

Primary Disconnects provide emergency stop and service disconnect switches for dispenser data and credit card data circuits.


Emergency Stop

In the event of an emergency stop, the Primary Dispenser Disconnect will disconnect the dispenser data and credit card communication circuit.

Safe Maintenance

Toggle switches, located behind a lockable cover, allow maintenance personnel to isolate the conductors of a single dispenser for servicing purposes.

NFPA® and NEC® Code Compliance

Dispenser Disconnects provide compliance with NFPA® and NEC® Code requiring emergency disconnect and maintenance disconnects at all motor fuel dispensing facilities.

ETHERNET PRIMARY DISPENSER DISCONNECTS

Primary disconnect for dispenser data and credit card data for dispensers equipped with Ethernet circuits for data communication.

Emergency Stop Connection

Connect to the emergency stop system by the means of a Class 2 transformer that is plugged into an outlet controlled by the emergency stop system.

Expandable

Expandable to allow disconnecting of additional secondary communication circuits such as intercom and media circuits. This is easily done by connecting the secondary disconnects to the remote expansion port located on the side of the primary disconnect.

Individual Disconnects

Individual disconnects for each circuit types allows the disconnect to be located where the conductors enter the building. This can eliminate costly additional wiring and downtime that maybe required to re-route conductors to a central location such as the electrical room, during a retrofit or site upgrade.

Certifications/Approvals

  • cUL Listed 1238
  • For compliance with NEC® 514.11 and NFPA® 30A Section 6.7 requirements for Emergency Disconnects at Motor Fuel Dispensing Facilities (controlled by E-Stop system).
  • For compliance with NEC® 514.13 requirements for Maintenance Disconnects at Motor Fuel Dispensing Facilities (switches to disconnect individual dispenser circuits for servicing).

General

Number of Dispenser Channels 8 or 16 Dispensers
E-Stop Control Input Powered by Class 2 24VAC
Transformer Connected to
120VAC E-Stop Controlled Outlet
Number of Conductors Disconnected
per Dispenser
8D and 16D Models = 1 Ethernet
Cable per Dispenser

88D = 2 Ethernet Cables per
Dispenser
Signal Circuit Rating Class 2, 48V Max, 3 Amp
Surge Protection Available No
Individual Channel Control Switches Yes
Lockable Channel Control Switches Yes
Secondary Remote Expansion
Output
Yes

Wall Mounted Primary Ethernet Disconnect Components & Dimensions

  1. Input Connection Panel
  2. Ethernet Input Jacks
  3. Output Connection Panel
  4. Ethernet Output Jacks
  5. Input Power Connection
  6. Service Disconnects (Behind Cover)
  7. Control Output to Secondary Disconnect Controller

EN Primary - Specs - Dims 1.psd

Rack Mounted Primary Ethernet Disconnect Components & Dimensions

  1. Input Connection Panel
  2. Ethernet Input Jacks
  3. Output Connection Panel
  4. Ethernet Output Jacks
  5. Input Power Connection
  6. Service Disconnects (Behind Cover)
  7. Control Output to Secondary Disconnect Controller

EN Primary - Specs - Dims 2.psd

Wall Mounted Primary Ethernet Disconnects

Model Number Description
DDS-EXP8D Primary Ethernet Dispenser Disconnect, 1 Ethernet Cable for 8 Dispensers
DDS-EXP88D Primary Ethernet Dispenser Disconnect, 2 Ethernet Cables for 8 Dispensers
DDS-EXP16D Primary Ethernet Dispenser Disconnect, 1 Ethernet Cable for 16 Dispensers

Rack Mounted Primary Ethernet Disconnects

Model Number Description
DDS-ERP8D Rack Mounted Primary Ethernet Dispenser Disconnect, 1 Ethernet Cable for 8 Dispensers
DDS-EXP88D Primary Ethernet Dispenser Disconnect, 2 Ethernet Cables for 8 Dispensers
DDS-ERP16D Rack Mounted Primary Ethernet Dispenser Disconnect, 1 Ethernet Cable for 16 Dispensers