Secondary Disconnect

Communication/Intercom Disconnects

Comm Intercom Secondary Disconnects - Hero.psd
Secondary Disconnect

Communication/Intercom Disconnects

Communication/Intercom Secondary Disconnects are designed to expand the number and type of circuits that can be disconnected. They are used for intercom wiring and can also be used to disconnect additional communication conductors connected to a dispenser.

Secondary Disconnects - Twisted Pair - Highlight.psd

SECONDARY DISCONNECTS

Secondary Communication/Intercom Disconnects expand the capability of the primary disconnect. They connect to and are controlled by any Primary Disconnect via the included 6’ and 25’ DB-9 cables. These Secondary Disconnects are used for communication circuits with 4 or 8 conductors per dispenser.


Emergency Stop

Secondary Disconnects connect to the primary disconnect allowing secondary circuit conductors to be disconnected when the emergency stop system is activated.

Intercom Disconnect

Handles any intercom configuration that uses 1 call button & 1 speaker, 2 call buttons, or 2 speakers per dispenser OR an intercom configuration that uses 2 call buttons & 2 speakers per dispenser.

Easy Installation

Individual disconnects for each circuit types allows the disconnect to be located where the conductors enter the building. This can eliminate costly additional wiring and downtime that maybe required to re-route conductors to a central location such as the electrical room, during a retrofit or site upgrade.

Certifications/Approvals

  • UL (1238) Listed
  • cUL (CSA 22.2) Listed
  • For compliance with NEC® 514.11 and NFPA® 30A Section 6.7 requirements for Emergency Disconnects at Motor Fuel Dispensing Facilities (controlled by E-Stop system).
  • For compliance with NEC® 514.13 requirements for Maintenance Disconnects at Motor Fuel Dispensing Facilities (switches to disconnect individual dispenser circuits for servicing).

General

Number of Dispenser Channels 8 or 16
E-Stop Control Input Connects to Remote Control
Output of Primary Disconnect
Number of Conductors Disconnected
per Dispenser
4 Conductors + (Shield – Not
Disconnected)

8 Conductors + (Shield – Not
Disconnected)
Signal Circuit Rating Class 2, 48V Max, 3 Amp
Surge Protection Available No
Individual Channel Control Switches Provided by the Primary
Disconnect
Secondary Remote Expansion
Output
Yes

8 Dispenser, 4 Conductor Communication/Intercom Secondary Disconnects Components & Dimensions

  1. Active Status Indicators
  2. Control Input
  3. Control Output
CID Secondary - Specs - Dims 1.psd

8 Dispenser, 8 Conductor & 16 Dispenser, 4 Conductor Communication/Intercom Secondary Disconnects Components & Dimensions

  1. Active Status Indicators
  2. Control Input
  3. Control Output
CID Secondary - Specs - Dims 2.psd

8 Dispenser, 4 Conductor Communication/Intercom Secondary Disconnects

Model Number Description
DDS-8DB4C Communication/Intercom Secondary Disconnect, 4 Conductors 1-8 Dispensers (for (4) intercom conductors for (8) dispensers ie: (1) call button & (1) speaker per dispenser)

8 Dispenser, 8 Conductor & 16 Dispenser, 4 Conductor Communication/Intercom Secondary Disconnects

Model Number Description
DDS-8DA44CE Communication/Intercom Secondary Disconnect, 8 Conductors 1-8 Dispensers (for (8) intercom conductors for (8) dispensers ie: (2) call buttons & (2) speakers per dispenser)
DDS-16DA4CE Communication/Intercom Secondary Disconnect, 4 Conductors 1-16 Dispensers (for (4) intercom conductors for (16) dispensers ie: (1) call button & (1) speaker per dispenser)