⅓ & ¾ Hp Pumps
⅓ & ¾ Hp Pumps
FE PETRO® ¾ Hp fixed speed submersible pumps deliver consistent flow rates for low throughput fuels.
WE SET THE STANDARD
FE PETRO® brand submersible pumping systems set the standard by which all other fuel pumping systems are measured. With best-in-class flow rates and backed by a long history of dependability, FE PETRO® pumps are responsible for delivering fuel to thousands of customers around the globe, day in and day out.
Available as an option on AG compatible submersible turbine pumps, Advanced Protection defends STPs from accelerated corrosion caused by the acedic byproduct of microbial activity.
Turbine Pump Interface is a powerful tool that creates a network between your FE PETRO® STP controllers and EVO™ Series ATGs. Through TPI, the tank gauge can be programmed to respond to faults in the submersible pumping system and react with intelligence that pump controllers alone cannot.
SEE TPI IN ACTIONPump In Water Automation
When the water level in a tank approaches the pump intake, the tank gauge will enter alarm mode and automatically shut down the pump, protecting the system and customer vehicles.
Leveling & Priority Modes
When managing two storage tanks of the same product ‘Leveling Mode’ can keep both tanks at the same percentage full without the use of a syphon bar between the two tanks.
Remote Pump Interaction
By networking the intelligent controllers to the fuel management system via TPI, a technician can remotely connect to the site to review the logged event history and view the status.
An Intake Filter Screen (IFS) provides fuel filtration for the entire system down to about the size of a grain of sand (0.009” openings). It’s designed to keep harmful debris, sediment, and tank corrosion from entering the pumping system and creating service events including dispenser filter changes.
Intake Filter Screens
4" Submersible Pump Components & Key Dimensions
1. Manhole
2. Leak Detector
3. Manifold
4. Containment Sump
5. 4" Riser
6. Tank Adapter
7. Tank Manway
8. Column Pipe
9. Variable Length Coupler
10. Pump Motor Assembly (PMA)
11. End bell
12. Line Test Port, ¼" NPT
13. Leak Detector Port, 2" NPT
14. Syphon Port, ¼" NPT
15. Tank Port, ¼" NPT
16. Riser Pipe, 4" NPT
17. Discharge Outlet, 2" NPT
Notes:
1. Effective tank diameter (ETD) = Inside tank diameter (to top of 4" bung), including tank manway and/or sump adapter.
2. Model length (A) = ETD plus riser length minus bottom clearance minus 1" thread engagement.
3. Riser length (B) = Bury depth (to top of tank) minus pump head clearance minus tank manway and/or minus sump adapter.
Optional Features
Biofuel Blend Compatibility
FE PETRO® pumps are UL listed with both UL79A (up to 85% Ethanol) and UL79B (up to 20% or 100% Biodiesel).
Variable Length
The patented telescoping pump shaft lets installers adjust the length of the pump onsite for the perfect fit.
Advanced Protection
Stop corrosion in its tracks. Special powder-coated, e-coated, and stainless steel components defend your pump in the tank and in the sump from accelerated corrosion.
Turbine Pump Interface
Remote enhanced pump monitoring and control including pump-in-water automation, clogged intake escalation, tank leveling, and tank priority.
Intake Filter Screen
Avoid system damage, pumping slowdowns, and reduce filter changes by keeping harmful tank debris, sediment, and corrosion from entering the pumping system with this factory-installed option.
Standard Features
Active Air Eliminator
FE PETRO® STPs come standard with active air elimination, which eliminates air through the highest point in the pump head at all times when the pump is running, assuring air does not pass into discharge piping.
Safety and Ease of Maintenance
FE PETRO® STPs include a contractor electrical disconnect, which requires loosening only one bolt, allowing motor wiring to be disconnected without venting the dangerous tank vapors into the sump when servicing FE PETRO® submersible products.
Simple Servicing
If ever required, the pump can be easily removed from the tank by unthreading three bolts. There is no need to disconnect the syphon system or to remove the leak detector from the system to service the STP.
Manual Pressure Relief
As a standard FE PETRO® feature, a vent screw is provided to bleed line pressure to zero when necessary. By turning this screw, product is diverted back to the tank, dropping line pressure to zero. This reduces fuel discharged into the sump manhole or dispenser pan during servicing, further protecting service technicians and the environment.
Outlast, Outperform with Franklin Electric Inside
FE PETRO® STPs are powered by the legendary Franklin Electric motor and built for long term performance. Franklin Electric-powered submersible pumps provide maximum uptime and a proven track record in the fueling industry that spans more than four decades. They feature best-in-class flow rates and a long history of dependability.
Quality Certification
Franklin Fueling Systems is an ISO 9001 Certified Manufacturer.
General
- ¾ Hp fixed speed models are available in variable length and fixed length options.
- Check valve: 2¾" diameter fluorocarbon seal constructed with cast aluminum body and steel backing washer.
- Pressure relief valve: available in four pressure relief settings, integral to check valve. Standard model relieves at 40 psi and resets above 35 psi.
- Syphon: venturi-type syphon primer supplied with every submersible. Syphon check valve and secondary syphon sold separately.
- Air eliminator: every submersible includes a tank return path with one-way check valve to provide active air elimination.
- Electrical disconnect: electrical yoke for positive contractor disconnect during service.
60 Hz Pump Motor
- ¾ Hp fixed speed, 3450 rpm, two-stage centrifugal type pump motor with integral, automatic thermal overload protection.
- ¾ Hp models have a max. pressure of 30 psi.
50 Hz Pump Motor
- ¾ Hp fixed speed, 2875 rpm, two-stage centrifugal type pump motor with integral, automatic thermal overload protection.
- ¾ Hp models have a max. pressure of 2.55 bar.
60 Hz Power Requirements
- ¾ Hp fixed speed models require single-phase, 208-230 VAC, 60 Hz incoming power.
- ¾ Hp fixed speed models incorporate a starting and running capacitor, with internal bleed resistor, rated 370 Volt, 15 microfarad.
- SPGC-220 single-phase Guardian Controllers and STP-CBS single-phase control boxes are available for ⅓ and ¾ hp pump control.
- ¾ hp max. motor draw: 7 Amps.
50 Hz Power Requirements
- 75B fixed speed models require single-phase, 200-250 VAC, 50 Hz incoming power. 75C fixed speed models require three-phase, 380-415 VAC, 50 Hz incoming power
- 75B fixed speed models incorporate a starting and running capacitor, with internal bleed resistor, rated 440 Volt, 15 microfarad.
- SPGC-220 single-phase Guardian™ Series Controllers and STP-CBBS single-phase control boxes are available for 75B pump control.
- STP-SCIIIC three-phase smart controller and STP-CBB3C three-phase magnetic starter are available for 75C control
- ¾ Hp max. motor draw: 75B 6 Amps, 75C 3 Amps.
Liquid Compatibility
- Max. liquid viscosity: 70 SSU at 60 °F (15 °C).
- Standard STP models are UL and cUL listed for fuel mixtures containing up to 10% ethanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAME with gasoline.
- STPAG/STPAP (AG compatible) models are UL listed for fuel mixtures containing diesel fuel with up to 20% Biodiesel, 100% Biodiesel, up to 85% ethanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAME with gasoline.
- ¾ hp fixed speed models can also be used with diesel fuels, fuel oils, kerosene, Avgas, and jet fuels in a non-gelled pourable state.
- All wetted elastomers are made of a high grade, fluorocarbon compound.
Fuel Compatibility for All Submersible Turbine Pumps
STP Standard Submersible Turbine Pumps with Fixed or Variable Speed Pump Motor Assembly
- UL79 for petroleum dispensing products intended for use with gasoline or gasoline/ethanol blends with nominal ethanol concentrations up to 10 percent (gasohol, E10), diesel fuel, diesel/biodiesel blends with nominal biodiesel concentrations up to 5 percent (B5), kerosene, or fuel oil.
- 20% MTBE, 20% ETBE or 17% TAME with gasoline.
STPAG, STPAP, IST, ISTAP Alcohol-Grade Compatible and Advanced Protection Fixed or Variable Speed Submersible Turbine Pumps
- UL79A for gasoline and gasoline/ethanol blends with nominal ethanol concentrations up to 85 percent (E0 - E85) for products intended for use with gasoline or gasoline/ethanol blends with nominal ethanol concentrations up to 85 percent (E85).
- 20% MTBE, 20% ETBE or 17% TAME with gasoline.
- UL79B for diesel fuel, biodiesel fuel, diesel/biodiesel blends with nominal biodiesel concentrations up to 20 percent (B20), kerosene, and fuel oil for products intended for use with diesel fuel, biodiesel fuel, diesel/biodiesel blends with nominal biodiesel concentrations up to 20 percent (B20), kerosene or fuel oil.
- 100% biodiesel.
Approvals
- cULus listed.
- Consult factory for applicable approvals.
¾ Hp Fixed Speed Pump Performance Chart - 60 Hz
For 50 Hz performance charts, please see the 50Hz-Submersible Turbine Pumps-Datasheet in Downloads.
¾ Hp Fixed Speed Submersible Pump Ordering Guide
A typical turbine model designation has up to five components to define the pump being supplied as follows:
STP XXXXX Y - A - B
STP = Basic Model Designation
XXXXX = Factory Installed Options (Model designations may include one or more of the following characters in alphabetical order.)
AP = Advanced Protection with powder-coated, e-coated, and stainless steel components, alcohol-gasoline compatible (up to E85, up to B20, and B100) (Note standard models up to 10% ethanol capable)
AG = Alcohol-gasoline compatible (up to E85, up to B20, and B100) (Note standard models up to 10% ethanol capable)
F = Floating suction adapter (1½" NPT female adapter)
K = Intake filter screen (IFS, factory installed to PMA)
*R = Model R check valve (24 psi relief / 22 psi reset for PLLD)
*W = Model W check valve (16 psi relief / 13 psi reset for PPM4000)
Y = Pump Motor Horsepower Rating
75 = ¾ Hp fixed speed
75B = ¾ Hp fixed speed, 50 Hz, single-phase
75C = ¾ Hp fixed speed, 50 Hz, three-phase
A = Model Length
VL1 = Variable length range #1. (⅓: 55" - 83", ¾: 57" - 86")
VL2 = Variable length range #2. (⅓: 86" - 147", ¾: 88" - 149")
VL3 = Variable length range #3. (⅓: 118" - 209", ¾: 120" - 212")
(Note VL2 models fit 94% of all known installations)
B = Riser Pipe Length (see diagram)
Riser pipe length is expressed as two numeric characters that indicate the total length of the riser in inches. Riser pipes are available from 7" to 60" in 1" increments (additional charge for risers 31" or longer).
Standard ¾ Hp Fixed Speed Submersible Turbine Pumps
Model | Description | Model Length Range Number | Model Length Range* |
STP75-VL1 | ¾ Hp fixed speed | VL1 | 57" – 86" |
STP75-VL2 | ¾ Hp fixed speed | VL2 | 88" – 149" |
STP75-VL3 | ¾ Hp fixed speed | VL3 | 120" – 212" |
Alcohol-Gas (AG) ¾ Hp Fixed Speed Submersible Turbine Pumps
Model | Description | Model Length Range Number | Model Length Range* |
STPAG75-VL1 | ¾ Hp AG fixed speed | VL1 | 57" – 86" |
STPAG75-VL2 | ¾ Hp AG fixed speed | VL2 | 88" – 149" |
STPAG75-VL3 | ¾ Hp AG fixed speed | VL3 | 120" – 212" |
STPAP75-VL1 | ¾ Hp fixed speed with Advanced Protection | VL1 | 57" – 86" |
STPAP75-VL2 | ¾ Hp fixed speed with Advanced Protection | VL2 | 88" – 149" |
STPAP75-VL3 | ¾ Hp fixed speed with Advanced Protection | VL3 | 120" – 212" |
Notes:
- STP models are compatible with fuel mixtures containing up to 10% ethanol with gasoline, up to 5% Biodiesel with diesel fuels, and 20% MTBE, 20% ETBE or 17% TAME with gasoline. STPAG/STPAP models are compatible with fuel mixtures containing diesel fuel with up to 20% Biodiesel, 100% Biodiesel, up to 85% ethanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAME with gasoline.
- All models are supplied with a standard check valve unless factory option “R” or “W” is specified.
- All above models require single-phase, 208-230 VAC, 60 Hz incoming power.
- 4" riser pipe, if supplied locally, must be 4½" OD by 3/16" WT tubing.
- For riser pipe lengths 31" to 60", additional charges apply. (Call Customer Service for lead times.)
*Model length (A) defined as the dimension from turbine manifold bottom to pump motor inlet
Factory Installed Options
Specified in model number at time of STP order.
Model | Description |
F | Floating suction adapter, 1½" NPT female, must be factory installed |
K | IFS (intake filter screen) factory assembled to pump motor assembly |
R | Model R check valve, factory installed, for Veeder-Root® PLLD Line Leak |
W | Model W check valve, factory installed, for Red Jacket PPM4000 Line Leak |
¾ Hp fixed speed specific accessories - 60Hz
Model Number | Description |
---|---|
400137908 | Syphon check valve, alcohol-gasoline compatible (when ordered with STP/IST) |
400818921 | STP-CBS, single-phase control box, with switch and lockout, 120 Volt coil |
402312931 | STP-DHI + SPGC-220 Guardian Series™ Single-Phase Controller bundle (220 Volt supply, 110 Volt hook) |
402313921 | STP-DHI-CBS, combo DHI with factory-wired STP-CBS single-phase control box |
402459931 | Model 65 psi check valve (for secondary manifolded STPs with Veeder-Root® PLLD), AG compatible |
402507930 | Secondary syphon kit (when two syphon primes are required for one STP) |
5800100220 | SPGC-220 Guardian Series™ Single-Phase Controller, 220 Volt |
5800300100 | STP-DHI, dispenser hook isolation for 110 Volt dispenser handle switches, up to eight each |
¾ Hp fixed speed specific accessories - 50Hz
Model Number | Description |
---|---|
400137937 | Syphon check valve, alcohol-gasoline compatible |
400818922 | STP-CBBS, single-phase control box, with switch and lockout, 240 Volt coil |
401220965 | STP-CBB3C, three-phase 380-415 VAC magnetic starter |
402312932 | STP-DHIB + SPGC-220 Guardian Series™ Single-Phase Controller bundle (220 Volt supply, 240 Volt hook) |
402313922 | STP-DHIB-CBBS, combo DHI with factory-wired STP-CBBS single-phase control box |
402459931 | Model 65 psi check valve (for secondary manifolded STPs with Veeder-Root® PLLD), AG compatible |
402507930 | Secondary syphon kit (when two syphon primes are required for one STP) |
5800100220 | SPGC-220 Guardian Series™ Single-Phase Controller, 220 Volt |
5800300200 | STP-DHIB, dispenser hook isolation for 240 Volt dispenser handle switches, up to eight each |
5800103300 | STP-SCIIIC, three phase 380-415 VAC smart controller |
4" STP Accessories & Parts
Visit the Accessories & Spare Parts page for a full listing of available products.
Accessories & PartsFeatured
Brochures
Title | Type | Size | |
---|---|---|---|
FFS-0796 Submersible Turbine Pumps Datasheet.pdf | 1.95 MB | ||
FFS-0616 (60Hz) Pump Selection Guide.pdf | 9.11 MB | ||
FFS-0648 (50Hz) Pump Selection Guide.pdf | 7.67 MB | ||
FFS-0801 (50Hz) Submersible Turbine Pumps Datasheet.pdf | 4.72 MB | ||
FFS-0383 (50 Hz) 3_4 Hp Fixed Speed STP Datasheet.pdf | 2.11 MB |
Catalogs
Title | Type | Size | |
---|---|---|---|
FFS-0216 (UL) FFS Product Catalog.pdf | 62.67 MB | ||
FFS-0807 (EN) Product Catalogue.pdf | 48.43 MB | ||
FFS-0367 (UL) Site Starters Ordering Guide.pdf | 52.07 MB |
Manuals
Title | Type | Size | |
---|---|---|---|
FFS-0801 (50Hz) Submersible Turbine Pumps Datasheet - Russian.pdf | 4.19 MB | ||
400604005 STP-IST Installation Guide.pdf | 2.88 MB | ||
400289002 PMA Replacement Guide.pdf | 1.23 MB | ||
SB005 Syphon System Testing.pdf | 0.23 MB |